+86-136-52756687
Dissmann Fuse HD10V.J03 Series 10 X 38 Fuse For Charging Pile Module

Dissmann Fuse HD10V.J03 Series 10 X 38 Fuse For Charging Pile Module

Meet the requirements:UL248/GB13593/IEC60268/GB31465.
Anfon ymchwiliad
Product Details ofDissmann Fuse HD10V.J03 Series 10 X 38 Fuse For Charging Pile Module

Dissmann fuse HD10V.J03 series 10 x 38 fuse for Charging pile Module

HD10PVJ03

 

Basic information of the Charging Pile Module Fuse:

  • Rated voltage:750VDC/AV
  • Rated current:10-50A
  • Protection type:aR
  • Breaking capacity: 33KA (10-20A);6KA(25-50A)
  • Meet the requirements:UL248/GB13593/IEC60268/GB31465
  • UL Certification:JDYX2.E343461 / JDYX8.E343461

 

Product type:

HD10V.J03 750VDC
Product code Rated Current
A
I²t power consumption
(A²Sec) W
HD10V.J03 10 80 1.8
HD10V.J03 15 150 2.6
HD10V.J03 16 200 2.8
HD10V.J03 20 330 3.5
HD10V.J03 25 480 4.3
HD10V.J03 30 730 5.6
HD10V.J03 32 780 6.0
HD10V.J03 35 900 6.6
HD10V.J03 40 1400 7.6
HD10V.J03 50 2200 9.6

 

Overall dimensions of the product(mm)

Dissmann fuse 10 x 38 HD10VJ03

Dissmann fuse 034

Normal use conditions and parameter correction:

The fuse operates under the following normal conditions of use, without additional correction.

When the normal use conditions are exceeded, if they are within the allowable use conditions, some parameters may need to be corrected or consulted. If the scope of allowable use conditions is exceeded, our company should be consulted and the work adaptability evaluation and test of the conditions should be carried out.

It is recommended that the current value of long-term current flow should not be greater than 80% of the rated current.

Please refer to the temperature evaluation curve for the use of overtemperature.

Ambient air temperature

Normal use conditions: - 5 ° C~40 ° C.

Allowable use conditions: - 40 ° C~85 ° C.

 

During packaging and transportation, rain and snow and mechanical damage shall be avoided.


Storage temperature

Product storage temperature:

-40°C~105°C。

The relative humidity is not more than 70% at 40 ° C;

The relative humidity at 30 ° C is not more than 80%;

Under 20 ° C, the relative humidity is not more than 90%.

Packaging storage temperature:

-40°C~70°C。

The relative humidity is not more than 40% at 40 ° C;

The relative humidity is not more than 50% at 30 ° C;

Under 20 ° C, the relative humidity is not more than 90%, and there is no condensation.

 

More fuses can be used for Charging pile:

Dissmann fuse for charging pile and power module

 

Tagiau poblogaidd: dissmann fuse hd10v.j03 series 10 x 38 fuse for charging pile module, China, manufacturers, suppliers, factory

Anfon ymchwiliad

(0/10)